Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Clin Chem Lab Med ; 2022 Nov 17.
Article in English | MEDLINE | ID: covidwho-2230715

ABSTRACT

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.

2.
Clin Chem Lab Med ; 58(12): 2047-2061, 2020 09 13.
Article in English | MEDLINE | ID: covidwho-760723

ABSTRACT

Objectives Hydroxychloroquine (HCQ) is an anti-malarial and immunomodulatory drug reported to inhibit the Corona virus, SARS-CoV-2, in vitro. At present there is insufficient evidence from clinical trials to determine the safety and efficacy of HCQ as a treatment for COVID-19. However, since the World Health Organisation declared COVID-19 a pandemic in March 2020, the US Food and Drug Administration issued an Emergency Use Authorisation to allow HCQ and Chloroquine (CQ) to be distributed and used for certain hospitalised patients with COVID-19 and numerous clinical trials are underway around the world, including the UK based RECOVERY trial, with over 1000 volunteers. The validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of HCQ and two of its major metabolites, desethylchloroquine (DCQ) and di-desethylchloroquine (DDCQ), in whole blood is described. Methods Blood samples were deproteinised using acetonitrile. HCQ, DCQ and DDCQ were chromatographically separated on a biphenyl column with gradient elution, at a flow rate of 500 µL/min. The analysis time was 8 min. Results For each analyte linear calibration curves were obtained over the concentration range 50-2000 µg/L, the lower limit of quantification (LLOQ) was 13 µg/L, the inter-assay relative standard deviation (RSD) was <10% at 25, 800 and 1750 µg/L and mean recoveries were 80, 81, 78 and 62% for HCQ, d4-HCQ, DCQ and DDCQ, respectively. Conclusion This method has acceptable analytical performance and is applicable to the therapeutic monitoring of HCQ, evaluating the pharmacokinetics of HCQ in COVID-19 patients and supporting clinical trials.


Subject(s)
Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid , Hydroxychloroquine/blood , Hydroxychloroquine/metabolism , Tandem Mass Spectrometry , Calibration , Humans , Limit of Detection , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL